Improved Validation for DI51599 - Electricity Smart Meter Equipment (ESME ID)
Summary
A DNO has raised an issue with the ESME ID data stored in MPRS. Some of the ESMEs are passing MPRS basic validation but are being rejected by the proposed Metering Service preventing a change of service.
Latest update and next planned activity
Date of latest update
Latest Update
18/11/2026 - The Change Report (Proposal Plan) was approved by the REC Change Panel
Impacts Overview
Impacted REC Parties and Market Participants
Data Services (DS)
Other (Other)
Impacted REC Documents
Schedule 14 - Metering Operations
Impacted REC Services
Electricity Retail Data Service (ERDS)
Other Industry Codes impacted
Balancing and Settlement Code (BSC)
Smart Energy Code (SEC)
Priority and rationale
Standard
Solution development
Problem Statement
A DNO has raised an issue with the ESME ID data stored in MPRS. Some of the ESMEs are passing MPRS basic validation but are being rejected by the proposed Metering Service preventing a change of service (Rejection of IF-033 with IF-035 Response R). Basic REC R032 Validation on IF-005/D0312: XX-XX-XX-XX-XX-XX-XX-XX (0-9, A-Z)
Workgroup
Has a Workgroup supported the development of the Change Proposal?
No
Documents Library
There is currently no Change Plan.
Original submission
Change details
Daniel Tadecicc0 - St Clements Services (MPRS)
13 Aug 2026
Change details
Improved Validation for DI51599 - Electricity Smart Meter Equipment (ESME ID)
A DNO has raised an issue with the ESME ID data stored in MPRS. Some of the ESMEs are passing MPRS basic validation but are being rejected by the proposed Metering Service preventing a change of service (Rejection of IF-033 with IF-035 Response R).
Basic REC R032 Validation on IF-005/D0312:
XX-XX-XX-XX-XX-XX-XX-XX
(0-9, A-Z)
Basic REC R032 Validation on IF-005/D0312:
XX-XX-XX-XX-XX-XX-XX-XX
(0-9, A-Z)
Preventing Metering Services from accepting IF-033 appointment requests due to an invalid ESME. Requires the currently appointed Metering Service to correct the data via an IF-005.
EES is displaying invalid ESME IDs.
EES is displaying invalid ESME IDs.
The minimum requirement would be to implement a regex for DI51599 in EDMS and the DIP Schema (DI-085-ESME-GUID):
Proposed Minimum Validation REGEX for a valid DCC GUID:
^[0-9A-Fa-f]{2}(-[0-9A-Fa-f]{2}){7}$
MPRS can be enhanced to adopt the validation performed by Smart DCC where an ESME is made up of three components:
Organisation Unique Identifier
Manufacture Model or Device Type
Unique Serial Number
The ESME would need to be validated against a standing data set provided to MPRS
Proposed Minimum Validation REGEX for a valid DCC GUID:
^[0-9A-Fa-f]{2}(-[0-9A-Fa-f]{2}){7}$
MPRS can be enhanced to adopt the validation performed by Smart DCC where an ESME is made up of three components:
Organisation Unique Identifier
Manufacture Model or Device Type
Unique Serial Number
The ESME would need to be validated against a standing data set provided to MPRS
-
Impacts
Electricity
Switching experience
-
Schedule 14 - Metering Operations
-
No details provided
-
No details provided
-
Data Item Catalogue
DI51599 - Electricity Smart Meter Equipment (ESME ID)
MTD Updates to SMRS - MM20035 IF-005
MTD Updates to SMRS - MM20035 IF-005
No details provided
DIP API Schema
Electricity Retail Data Service
-
Data Services, DCC, Distribution Network Operators, EES Users, Meter Operator Agent
Meter Data Retrieval Agent (MDR)
Balancing and Settlement Code (BSC), Smart Energy Code (SEC)
Possible change BSCP706 to specify the enhanced MPRS validation
SEC change to supply the standing data to MPRS & data cleanse for the current ESME ID Data held in EES
SEC change to supply the standing data to MPRS & data cleanse for the current ESME ID Data held in EES
-
No details provided
Priority & timing
No
-
Development: No
Implementation: After M15 so a change does not have to made to the D0312.
Implementation: After M15 so a change does not have to made to the D0312.
No
No details provided
Switching experience