DI50175

Meter Period Tag

Local Catalogue Reference
J0378
Data Type
String
Owner
Balancing and Settlement Code Company
Description
For HH meters, the meter registers that an activity or error has occurred for each half hour, by setting a tag or alarm associated with the period value.
Logical Length
16
Logical Decimal Length
0
Physical Length
16
Data Type Format Rule
Edifact Level B DTS Variant
Notes

Data Enumerations

Data Enumerations
Value Description
Value bit 10 Description MS - Change to Meter Standing Data
Value bit 11 Description RR - Reverse Running
Value bit 12 Description LA - Level 2 Access
Value bit 3 Description BM - Battery Maintenance Flag
Value bit 4 Description CF - Clock Failure
Value bit 5 Description MD - MD reset flag, set for the day on which the MD was reset
Value bit 6 Description PO - 24 hour continuous power outage of the outstation
Value bit 7 Description PF - Phase/Power Failure
Value bit 8 Description MR - Metering Equipment Reset
Value bit 9 Description DT - Corrections to Date and Time
Value bits 0-2 Description L2 - Number of successful level two password accesses

Found in Market Messages

Market Messages this Data Item is found in
Market Message ID Local Catalogue Reference Message Name
Market Message ID MM00079 Local Catalogue Reference D0003 Message Name Half Hourly Advances